What Are the Key Specifications of a Group 24 Battery?
A Group 24 battery typically measures 10.25″ x 6.8″ x 8.9″ (LxWxH) and weighs 40-50 lbs. Its voltage is 12V, with cold cranking amps (CCA) ranging from 600-800 for starting batteries. Amp hour (Ah) capacity varies between 70-85Ah for lead-acid types, while lithium variants may reach 100Ah. Terminals are usually top-post design, compatible with most marine/RV applications.
What Is a Group Size 24 Battery?
What Is the Typical Amp Hour Range for Group 24 Batteries?
Flooded lead-acid Group 24 batteries deliver 70-85Ah at 20-hour rates. AGM (absorbent glass mat) versions often provide 75-90Ah due to denser active material. Lithium iron phosphate (LiFePO4) batteries achieve 100-120Ah in the same size. Actual capacity depends on discharge rate – a 100Ah lithium battery may yield 80Ah at 1C (100A) discharge due to Peukert effect.
Top 5 best-selling Group 14 batteries under $100
Product Name | Short Description | Amazon URL |
---|---|---|
Weize YTX14 BS ATV Battery ![]() |
Maintenance-free sealed AGM battery, compatible with various motorcycles and powersports vehicles. | View on Amazon |
UPLUS ATV Battery YTX14AH-BS ![]() |
Sealed AGM battery designed for ATVs, UTVs, and motorcycles, offering reliable performance. | View on Amazon |
Weize YTX20L-BS High Performance ![]() |
High-performance sealed AGM battery suitable for motorcycles and snowmobiles. | View on Amazon |
Mighty Max Battery ML-U1-CCAHR ![]() |
Rechargeable SLA AGM battery with 320 CCA, ideal for various powersport applications. | View on Amazon |
Battanux 12N9-BS Motorcycle Battery ![]() |
Sealed SLA/AGM battery for ATVs and motorcycles, maintenance-free with advanced technology. | View on Amazon |
Chemistry | Ah Range | Efficiency |
---|---|---|
Flooded Lead-Acid | 70-85Ah | 75% |
AGM | 75-90Ah | 95% |
Lithium | 100-120Ah | 98% |
How Do Battery Chemistry and Design Affect Amp Hours?
Lead-acid batteries use lead dioxide plates and sulfuric acid electrolyte, limited by plate thickness and sulfation. AGM batteries employ compressed glass mats for better charge acceptance (up to 95% efficiency vs 75% for flooded). Lithium batteries utilize cobalt-free cathodes and graphene-enhanced anodes, achieving 2000-5000 cycles versus 300-500 for lead-acid. Case design impacts plate count – Odyssey’s Group 24 PC1500 fits 23 thin plates vs standard 11.
What Are Real-World Applications for Group 24 Batteries?
Marine trolling motors require 50Ah for 2hp/24V systems running 4 hours. RV house batteries need 200Ah (parallel dual Group 24) for 1kW daily usage. Solar storage systems pair 4×Group 24 lithium (400Ah) with 2000W inverters. Automotive applications include diesel truck dual-battery setups, with 750CCA models supporting 1500W audio systems.
In emergency backup systems, two Group 24 AGM batteries can power essential medical equipment for 8-12 hours. For marine refrigeration units, a single lithium Group 24 battery typically provides 3 days of continuous cooling. Off-grid cabins often combine four Group 24 batteries with solar panels to create 48V systems capable of running air conditioning units. Recent advancements in battery management systems now allow Group 24 banks to automatically prioritize power distribution between engine starting and accessory loads.
Application | Battery Count | Runtime |
---|---|---|
RV Refrigerator | 1 | 18-24 hours |
Fish Finder | 1 | 10-12 hours |
Camping Lights | 1 | 30-40 hours |
How to Maintain and Optimize Group 24 Battery Capacity?
Equalize flooded batteries monthly at 15.5V for 2 hours. AGM requires 14.7V absorption charging. Lithium needs 14.6V balancing. Use temperature-compensated charging: -3mV/°C/cell for lead-acid. Store at 50% SoC with <40°C ambient. Clean terminals with baking soda solution to prevent 0.3V voltage drop. Check torque: 8-10 N·m for SAE posts. Rotate parallel batteries annually to equalize resistance.
Implement a quarterly maintenance routine using hydrometers for flooded batteries (specific gravity should read 1.265-1.299). For lithium batteries, calibrate the BMS every 6 months by performing a full discharge/charge cycle. Use infrared thermometers to detect hot spots during charging – terminal temperatures shouldn’t exceed 50°C. Install voltage monitoring displays to track state-of-charge accuracy within ±2%. When storing batteries over winter, disconnect all loads and use maintenance chargers that switch between float and pulse modes.
Expert Views
“Group 24’s 85Ah limit stems from BCI case dimensions. Our graphene-anode prototype achieves 135Ah in Group 24 through 3D electrode printing. However, thermal management becomes critical – we use phase-change materials to maintain 25-35°C during 2C charging. The future lies in hybrid capacitors augmenting lead batteries for 200% cycle life improvement.”
FAQ
- Can I replace flooded with AGM in my Group 24 battery?
- Yes, but ensure your charging system provides 14.4-14.7V absorption voltage. AGM requires 25% less charge time but 10°C lower temperature compensation.
- How long will 100Ah Group 24 battery run a 50W load?
- At 50W (4.16A), 100Ah × 80% DoD = 19.2 hours. Factor in 90% inverter efficiency: 17.3 hours.
- Are Group 24 and 27 batteries interchangeable?
- Group 27 is 12% longer (12.06″ vs 10.25″). Check tray space – some vehicles allow modification. Capacity increases 20% (e.g., 85Ah to 105Ah in lead-acid).